External Device
Servers Wireless
- WiBox®
- WiSpanTerminal Server
ETS Family
- ET8PS
- ETS16PS
- ETS16PR
- ETS32PR
Advanced Security SecureBox®
- SDS1101
- SDS1100
- SDS2100
Commercial
- EDS8/16/32
- EDS4100
- UBox®
- UDS1100
- UDS2100
- UDS-10 NEW
- UDS10/ 100-IAP
- UDS200
- MSS100
- MSS4
- MSS485-T
- CoBox-FL
Industrial
- IntelliBox®-I/O NEW
- UDS1100-IAP
- UDS-10-IAP
- UDS100-IAP
- XPress-I/O NEW
- XPress-DR+™
- XPress-DR+ Wireless
- XPress-DR™
- XPress-DR-IAP
- CoBox-FL-IAP |
Industrial Device Servers
IntelliBox-I/O 2100
Highlights
* Network-enables equipment with SSH/SSL enterprise-grade security
* Proactively monitors the attached equipment
* RoHS logoTakes automatic control and/or troubleshooting action based on
user-defined settings
* Automated reporting and notification via e-mail or RSS feed
* Secure remote access and control of digital I/O and relays
* 10/100 Ethernet interface with 1.5kv isolation (802.3 standard)
* Two serial ports (RS232 and RS422/485) with ESD protection and 1.5kv
isolation from incoming power
* Two optically-isolated digital I/Os
Fully Automate Your Remote Equipment with Real-time Event Management and
Reporting
IntelliBox®-I/O 2100 is a breakthrough in truly automated control
of remote equipment. Powered by Lantronix EventTrak™ technology, this
highly-advanced, programmable device server connects your equipment to an
IP network and monitors it to watch for events at specified intervals.
When an event occurs, IntelliBox automatically sends pre-determined,
user-defined command(s) to the equipment causing it to take appropriate
and/or corrective actions – without any user intervention. IntelliBox can
send email notification that the event was detected and handled
accordingly.
True Autonomous Control with EventTrak
IntelliBox proactively monitors and controls remote digital I/O, dry
contact (relay) and RS232/422/485-based equipment. With built-in
EventTrak technology, IntelliBox can be set to query an attached device
at timed intervals then, depending on the results, take prespecified
action(s). In addition to monitoring a serial line the IntelliBox can
also monitor digital I/O. Fluid-level monitoring is a simple example – if
IntelliBox notices a digital float sensor drop to a ‘low level,’ it can
trigger a relay to start the fluid pump. When the level is restored the
relay is triggered to stop the pump. IntelliBox sends an email to the
user notifying them of the situation and the actions taken. Instead of
reacting to an event or problem, users are proactively notified that an
event occurred and the appropriate response automatically took place.
This also enables users to control networked equipment directly through
the serial or I/O port rather than depending on a PLC or SCADA server. In
some instances, several events should occur before action is taken.
EventTrak allows “Chain Definitions” (series of events/ actions) to be
defined. They can be saved, stored and transferred from one IntelliBox to
another, providing a great deal of flexibility for large-scale
deployment.
IntelliBox is ideal for alarms, fluid pumps, motor drives, lights, fans,
phone systems, access/control/alarm panels, HVAC equipment, PLC’s,
projectors, security cameras, proximity readers, card readers, etc.
Automated Reporting
IntelliBox consolidates the task of monitoring/reporting on multiple
pieces of equipment. Rather than query and review the output of each
device separately, users can configure the IntelliBox to query attached
equipment at configurable intervals and gather the returned data.
Incoming data can be sent via email or RSS feed, allowing hundreds of
devices to be monitored from one RSS-enabled web page. Incoming data can
be scanned for specific information. When it is detected, IntelliBox can
send an email flagged as “Important” along with the data and take
corrective action if needed.
Enterprise-grade Security and Data Center Standards
Equipped with the Lantronix Evolution OS™ Networking Operating System,
IntelliBox delivers enterprise-grade level networking security with
built-in SSH/SSL support. The hardened OS and mature protocol stack are
resilient to denial of service (DoS) and port mapping attacks and prevent
it from being used to bring down other networked devices. Evolution OS
uses familiar data-center standards such as a Cisco-like command line
interface (CLI) very similar to that used by routers and hubs,
simplifying configuration and enterprise network integration. It also
incorporates XML – a standard tool for web services, data transfer and
rich content management that encapsulates data into a text-based format.
Proactive Management for the Industrial Environment
Ideally suited for industrial applications, IntelliBox is equipped with
isolated serial, I/O and Ethernet ports and screw terminal connectors for
serial, I/O, relay and power. It supports Modbus TCP, Modbus ASCII and
Modbus RTU and is FM-approved for hazardous locations Class 1, Div. 2.
IntelliBox also features 15KV serial port ESD protection which protects
the IntelliBox from electrical overstress; ESD-protected I/O channels
(independent and optically isolated); wide -40°–75°C operational
temperature range; and flexible power with 9-30 VDC and 9-24 VAC input
range.
IntelliBox can act as a Modbus TCP slave, enabling Modbus TCP masters to
monitor the status of digital inputs and set the digital outputs and
relays. It can also be used as a “Modbus bridge” (Modbus TCP to Modbus
RTU/ASCII protocol converter) enabling users to connect RS232/RS485
Modbus RTU/ASCII devices to their Ethernet network to be controlled by
Modbus TCP masters (PLCs, OPC Servers, SCADA Software, etc).
back to toptop of page
Features / Specifications
Serial Interface
* 2 Serial ports: 1 RS232, 1 RS422/485 (4-wire/2-wire) with terminal
block connection
* Baud rate selectable from 300 to 230 Kbps
* Customizable baud rate support for non-standard serial speeds
* LED indicators for TXD and RXD activities
Serial Line Formats
Characters 7 or 8 data bits
Stop Bits 1 or 2
Parity odd, even, none
Flow Control
Hardware RTS/CTS
Software XON/XOFF
Modem Control
* CTS, RTS, DTR, DCD on Serial 1
Digital I/O
* 2 Independently configurable digital I/Os, configured via GUI set-up
Menu
* Opto-isolated to eliminate grounding issues
* Logically compatible with 3.3V level and also higher voltage levels
* Transient voltage and polarity reversal protection built in
Relay
* Contacts are capable of handling up to 8A resistive load
* Contacts are mechanically isolated to eliminate grounding issues
* Contacts are non-latching with Normally Open (NO) or Normally
* Closed (NC) for simple application such as power failure indication
Network Interface
* 1 RJ45 Ethernet port
* 10Base-T/100Base-TX
* Full or half duplex
* Auto-negotiating or hard coded
LED Indicators
* 10Base-T and 100Base-TX Link
* Ethernet Activity
* Serial Transmit Data
* Serial Receive Data
* Power / Status
Management
* Internal web server
* SNMP v2C (MIB-II, RS232MIB)
* Serial login
* Telnet/SSH login
* XML
* DeviceInstaller software
Power Input
* Removable screw terminal block connector
* 9-30 VDC or 9-24 VAC with chassis ground
* 2.3W
Environmental
Temperature -40°C to 75°C (-40° to 167°F) Operating
-40°C to 85°C (-40° to 185°F) Storage
Humidity 10% to 90% relative humidity, noncondensing
Agency Approvals
* UL, CSA, FCC, CE, TUV, CTick, VCCI, FM Class 1, Div. 2
Protocols Supported
* ARP, UDP/IP, TCP/IP, Telnet, ICMP, SNMP, DHCP, BOOTP, TFTP, Auto IP,
SMTP, FTP, DNS, Traceroute, HTTP
Industrial Application Protocols
* Modbus TCP, Modbus ASCII/RTU
CPU
* Lantronix DSTNI-EX 120 MHz clock, 256 KB SRAM, 16 KB Boot ROM Internal
CPU Memory
Flash Memory
* 4 MB Flash
* 2 MB SRAM
EEPROM
* 64 Kbits
Reset
* Recessed push button
Packaging
Case metal enclosure with wall mounts
- IP30 enclosure rating
Dimensions (L x W x H) 115 x 109 x 23 mm (4.54 x 4.30 x .90 in), terminal
blocks included
Weight 0.3 kg (0.63 lb) (10 oz)
Shipping Dimensions (L x W x H)
* 254 x 216 x 70 mm (10 x 8.5 x 2.75 in.)
Isolation
* 1.5 KVAC / 2.1 KVDC galvanic isolation between power input port and
Ethernet port (except chassis ground)
* 1.5 KVAC / 2.1 KVDC galvanic isolation between power input port and
serial ports
* 1.5 KVAC / 2.1 KVDC galvanic isolation between Ethernet port and serial
ports
* 1.5 KVAC / 2.1 KVDC opto-isolation between digital I/O ports and all
other ports
* 1.5 KVAC / 2.1 KVDC mechanical isolation between Relay contacts and all
other ports
* 8 KV direct contact, 15 KV air discharge, ESD protection on all serial
ports (IEC 1000-4-2, IEC 61000-4-2)
* 40 A (5/50 ns) EFT protection (IEC 61000-4-4), 12 A (8/20 us) lightning
protection (IEC 61000-4-5) on Ethernet port
* Transient voltage protection and ESD at power input with max
non-repetitive surge current 800 A (8/20 us) (IEC 61000-4-2)
* Transient voltage protection and ESD with max non-repetitive surge
power 600W peak (10/1000 us) at digital I/O ports
| If you would
like further information, please submit this form or contact us at
sales@nationaldatamux.com and we will get right back to you!
|
 |
Or
Call: 1.800.663.1141 now and speak to one of our sales
associates. |
|